PCF
Sealants and adhesives equipment
Metering packages
PCF Metering System
Precision Continuous Flow Metering and Dispense System
Advanced closed-loop technology assures a precise, continuous flow of material
Reduces material waste with superior flow control
Used in conjunction with a material supply system and robotics platform, the Graco PCF Metering System assures a precise, continuous flow of material. Closed-loop technology provides real-time adjustments for changes in material temperatures, viscosities, dispense rates or robot speeds – providing your operation with a highly precise, continuous dispense. System components include: Advanced Display Module, Fluid Plate, Graco CAN Cable and Gateway.
Handles a range of materials:
- Ambient, warm melt and hot melt materials to 400°F (204°C)
• Low to high viscosity materials
• Unlimited volume
For drivetrain gasketing, the Graco Dispense Analyzer helps you find and correct the smallest of errors - before your customers find them for you.
Features:
The next generation of precision metering
- Closed-loop "real-time" control ensures a precise, continuous dispense – improves part quality and reduces material waste
- Intuitive user interface simplifies setup, reduces training time
- Integrated USB interface for easy data downloads - allows for further analysis of process data
- Multiple gun capabilities for additional productivity - lets you program up to four guns
- Compact modular design - easy to install, integrate and maintain
- Low cost of ownership - fewer wear parts compared to shot meters
PCF |
|
Minumum Flow Rates |
25 cc/min with high-resolution (ambient) helical flow meter, 50 cc/min with heated helical flow meter |
Maximum Flow Rates |
7500 cc/min with high-resolution (ambient) helical flow meter, 22,500 cc/min with heated helical flow meter, 37,500 cc/min with separate flow meter |
Minimum Fluid Working Pressure (at regulator outlet) |
0.7 MPa/7.0 bar |
Air Supply Pressure Range |
0.4 – 0.8 MPa/4.1 – 8.3 bar, 10 Micron filtration required |
Fluid Filtration Required |
500 micron minimum |
Viscosity Range of Fluids |
10000 to 1000000 cps with helical flow meter |
Minimum Dispensed Shot Size |
3 cc with high-resolution (ambient) helical flow meter, 6 cc with heated helical flow meter |
Wetted Parts (meters and fluid plates) |
303, 304, 321, 17–4 stainless steel, tungsten carbide, PTFE, steel, fluoroelastomer |
Power Supply Voltage Range |
100–240 Vac, 50–60 Hz, single phase |
Operating Humidity Range |
0 – 90% non-condensing |
Operating Temperature Range |
|
Control Center |
4°C to 49°C |
Heated Fluid Plate |
4°C to 204°C |
204 CAmbient Fluid Plate |
4°C to 49°C |
Power Requirements |
|
100–240 Vac |
full load 1.4A, fuse rating-2.5A |
240 Vac |
full load-4A, fuse rating-4A |
Maximum Fluid working pressure |
|
Feed Pressure to Fluid Plate (cartridge regulator) |
41.1 MPa/414 bar |
Feed Pressure to Fluid Plate (mastic regulator) |
34.5 MPa/345 bar |
At regulator outlet |
31.0 MPa/310 bar |
At regulator outlet with electric heat components |
24.1 MPa/241 bar |
Materials:
Sealants – epoxy sealants and adhesives